NYC Code: 1 RCNY §27-01 – Stair and Elevator Signs in Buildings with At Least One Elevator, based on the PDF you uploaded:


Applicability

  • Applies to all buildings with at least one elevator, including:

    • Office buildings with >100 people above/below street level

    • Buildings with >500 total occupants

    • Any building subject to §27-390 (Local Law 16 of 1984)


? Required Signs at Elevator Landings

  • Fire Warning Sign (on every floor except the main entrance):

    • Must read: "IN CASE OF FIRE, USE STAIRS UNLESS OTHERWISE INSTRUCTED"

  • Floor Diagram Sign:

    • Must show current location, stairs, and elevator banks

    • May be omitted in residential (J-2) buildings if:

      • Stair is within line of sight

      • Stair is within 20 feet

      • Only one stair, two scissors stairs, or fire escape serving one apartment


? Sign Placement

  • Above the elevator call button

  • Top of sign: no higher than 6 feet from the floor

  • If space is limited:

    • Place on wall nearby or elevator door (exceptions apply)


Floor Numbering Signs

  • Must be installed inside stair enclosures on each floor

  • Must be on the stair side of the door, or nearby wall if no door


Stair & Elevator Identification

  • Each stair and elevator bank must have a letter label

  • Signs placed:

    • At elevator landing

    • On both occupancy and stair sides of stair doors


? Stair Re-entry Signs

  • For large occupancy buildings (Group E, >500 people):

    • Signs required at each stair door showing re-entry policy

    • Options include:

      • “NO RE-ENTRY FROM THIS STAIR”

      • “NO RE-ENTRY EXCEPT DURING FIRE OR EMERGENCY”

      • “RE-ENTRY ON THIS FLOOR”

      • “NO RE-ENTRY, NEAREST RE-ENTRY ON THE _ AND _ FLOORS”


? Size Requirements

  • Elevator landing sign: 2.5” × 10”

  • Floor diagram sign: 8” × 12”

  • Combined sign: 10” × 12”


? Lettering & Color

  • Bold, high-contrast lettering

  • Minimum letter/numeral sizes:

    • Regular signs: ½ inch

    • Floor numbers & elevator ID: 3 inches


? Materials & Attachment

  • Must use metal or durable materials

  • Fire-resistant vinyl decals allowed if printed on reverse

  • Must be securely attached


? Older Buildings & Compliance

  • Existing signs (pre-March 27, 1984) may be accepted if functional

  • Modifications allowed if standard placement causes hardship

  • All signs must be installed by October 1, 1985